Application example: Cone-shaped plugs for exposed concrete

Processing instructions:
     

Using a cone removing device, first remove the supporting cone.

 

Then clean the clamping position with the help of a wire or synthetic brush.

   
     

Mix the two-component adhesive by following manufacturer’s instructions.

 

Apply the adhesive to the pipe interior as well as the cone-shaped plug of the exposed concrete.

     
     

Insert the cone-shaped plug carefully in the position to be sealed and push it down firmly.

 

The adhesive will have hardened after about 12 hours.